Specific Instructions for Validated Methods
3M Molecular Detection Assay Listeria Protocols using 3M Modified Listeria Recovery Broth
AOAC® Performance Tested Methods
In an AOAC PTM study, the 3M Molecular Detection Assay Listeria was found to be an effective method for the detection of Listeria using 3M Modified
Listeria Recovery Broth. The matrices tested in the study are shown in Table 2. The limit of detection of the 3M Molecular Detection Assay Listeria
method is 1-5 colony forming units per validated test portion size.
Table 2: Enrichment protocols using 3M Modified Listeria Recovery Broth (mLRB)
Sample Matrix
Full fat cottage cheese
Beef hot dogs
Cold smoked salmon
Raw bagged spinach
AOAC PTM
#081203
Whole cantaloupe
Environmental
surfaces
Environmental
For Other
Dairy, Vegetables
Matrices
Meat, Poultry, Seafood, Fruit
(PTM) Certificate #081203
SM
Sample Size
Deli turkey
25 g
1 melon
Stainless
1 sponge
steel, concrete
Plastic
1 swab
1 sponge
25 g
25 g
3M mLRB Volume (mL)
225
Enough volume to allow
melon to float
[volume may be 1.5
times the weight of the
cantaloupe]
225
10
225
225
5
(English)
Enrichment
Enrichment Time
Temperature
(hr)
(±1°C)
37
26-30
37
24-28
37
24-28
37
28-30