Fuel supply
Injector supply
LUBRICATION CIRCUIT
Type of lubrication
Circuit fuel supply
Oil change including filter
(standard sump)
Oil quantity at minimum level
(standard sump)
Oil quantity at maximum level
Oil pressure at minimum speed
(with started engine)
Alarm for oil pressure too low
Oil cooling
COOLING CIRCUIT
Total capacity of the cooling circuit
(excluding radiator and relevant
pipes)
Setting pressure of the expansion
tank plug
Coolant
Opening value (start/finish) of
thermostatic valve
Coolant maximum temperature
alarm
ELECTRIC SYSTEM
Nominal voltage
Alternating current generator
(nominal voltage)
Alternating current generator
(nominal current)
Starter motor output
Recommended battery capacity
Battery breakaway current
SUCTION CIRCUIT
Maximum depression allowed with
new air filter
English
D753E3
liters (kg)
liters (kg)
3.8
liters (kg)
bar
bar
liters
bar
1.1
50% demineralised or distilled water and 50%
Petronas Paraflu Up (protective radiator fluid with
monoethylene glycol and organic inhibitor formulation
complying with ASTM D 3306 type 1 Standards)
°C
80 ± 2 / 95
°C
107
V
12
V
14
A
70
kW
2,2
Ah
110
A
880
mbar
30
23
D700-750E2_E3
D753TE3
Diaphragm pump
Mechanical rotary injection pump
Forced lubrication
Rotor pump
3.8
5
3
0,4
Oil/water cooler
1.1
80 ± 2 / 95
107
12
14
70
2,2
110
880
35
VM p/n 42432097F Ed.4 - 2015-05
D753IE3
GB
3.8
1.1
80 ± 2 / 95
107
12
14
70
2,2
110
880
35