Siemens SINAMICS S120 Manual De Listas página 2281

Ocultar thumbs Ver también para SINAMICS S120:
Enable SSM hysteresis filter
p9501.16 (0000 bin)
Load-side v_act
r9714[0]
Safe speed
recording
<1> Only for p9506 = 1 or 3 "Safety without encoder".
<2> Drive via PROFIsafe [2858].
<3> Drive via onboard interface for CU310-2 [2875].
<4> Drive via TM54F [2905].
1
2
DO: SERVO, VECTOR
SI Extended Functions - SSM (Safe Speed Monitor)
Enable SSM hysteresis filter
p9301.16 (0000 bin)
0.00...100.00 [ms]
p9545 (0.00)
1
0
0.00...100 000.00 [µs]
p9345 (0.00)
SI Mtn SSM hyst MM
0.0010...500.0000 [rpm]
p9347 (10.0000)
3
4
Si Mtn SSM v_limCU
SI Mtn SSM v_limMM
0.00...1000 000.00 [rpm]
0.00...1000 000.00 [rpm]
p9546 (20.00)
p9346 (20.00)
0
SI Mtn SSM hyst CU
0.0010...500.0000 [rpm]
p9547 (10.0000)
1
5
fp_2823_54_eng.vsd
07.11.12 V05.02.03
<1>
STO active
r9722.0
&
p9509.0 (1)
0
SSM (speed below limit value)
r9722.15
0
<2> <3> <4>
1
6
7
Function diagram
S120/S150/G130/G150
p9500 (12.00 ms)
8
- 2823 -
loading

Este manual también es adecuado para:

Sinamics s150