Missing enable signals
Missing enable signals prevent the drive going into the state "operation"
(Operation enabled: r0899.2 = 1 [2503]).
Bit No.
Meaning
0
1 = OFF1 enable missing
1
1 = OFF2 enable missing
2
1 = OFF3 enable missing
3
1 = Operation enable missing
4
1 = Armature short-circuit / DC braking, enable missing
5
1 = STOP2 enable missing
8
1 = Safety enable missing
9
1 = Infeed enable missing
10
1 = Ramp-function generator enable missing
11
1 = Ramp-function generator start missing
12
1 = Setpoint enable missing
15
1 = Quick stop enable missing
16
1 = OFF1 enable internal missing
17
1 = OFF2 enable internal missing
18
1 = OFF3 enable internal missing
19
1 = Pulse enable internal missing
20
1 = Armature short circuit / DC braking internal enable missing
[2701.8]
21
1 = STOP2 enable internal missing
25
1 = Function bypass active
26
1 = Drive inactive or not operational
27
1 = De-magnetization not completed
28
1 = Brake open missing
29
1 = Cooling unit ready signal missing
30
1 = Speed controller inhibited
31
1 = Jog setpoint active
p2810[0]
Logic operation
(0)
&
r2811.0
p2810[1]
(0)
AND operation
p2816[0]
(0)
1
r2817.0
p2816[1]
OR operation
(0)
1
2
DO: SERVO, VECTOR
Sequence control - Missing enable signals, line contactor control, logic operation
Missing enable sig
r0046
r0046.0
[3020.5]
r0046.1
r0046.2
Fault with
r0046.3
OFF3 reaction
r0046.4
r0046.5
r0046.8
r0046.9
r0046.10
r0046.11
r0046.12
<2>
r0046.15
r0046.12
r0046.16
r0046.17
r0046.18
From sequencer
[2610]
r0046.19
r0046.20
r0046.21
r0046.25
r0046.26
r0046.27
<2>
r0046.28
r0046.29
r0046.30
r0046.31
NOT operation
p2822[0]
r2823
1
(0)
r2823.0
p2822[1]
(0)
1
r2823.1
p2822[2]
1
(0)
r2823.2
p2822[3]
1
(0)
r2823.3
3
4
p0115[3] (2000.00 µs)
Control Unit
[3060.2]
0 = Internal quick stop
≥1
[3060.4]
[3070.2]
[3070.4]
≥1
[3060.2]
[3070.2]
Line contactor control
Close main con
Energize
p0870
contactor
(0)
≥1
r0863.1
[2130]...[2133]
Line contact feedb
p0860
(r0863.1)
[2120]...[2133]
ON/OFF monitoring
0...5000 [ms]
p0861 (100)
T
0
=1
≥1
Operation monitoring
<1> For VECTOR is valid: Factory setting 1000.00 µs.
<2> Only for VECTOR.
<2>
Only for AC/AC devices, diode infeed.
5
6
fp_2634_54_eng.vsd
20.02.18 V05.02.03
<1>
From the
line supply
DO
+24 V
DI
To the infeed
7
8
Function diagram
- 2634 -
S120/S150/G130/G150