Signal sources for ZSW2_ENC
Signal
Meaning
ZSW1.0
Reserved
ZSW1.1
Reserved
ZSW1.2
Reserved
ZSW1.3
1 = Fault present
ZSW1.4
Reserved
ZSW1.5
Reserved
ZSW1.6
Reserved
ZSW1.7
1 = Alarm present
ZSW1.8
Reserved
ZSW1.9
1 = Control requested
ZSW1.10
Reserved
ZSW1.11
Reserved
ZSW1.12
Slave-sign-of-life bit 0
ZSW1.13
Slave-sign-of-life bit 1
ZSW1.14
Slave-sign-of-life bit 2
ZSW1.15
Slave-sign-of-life bit 3
<1> Used in telegrams 81, 82, 83.
<2> The drive object is ready to accept data.
1
2
DO: ENC
PROFIdrive - ZSW2-ENC status word ENCODER interconnection
p2080[3] = r2139.3
p2080[7] = r2139.7
p2080[9] = r0899.9
<2>
3
4
Interconnection
[Function diagram]
[Function diagram]
parameters
signal source
internal status word
-
-
-
-
-
-
[2548.7]
-
-
-
-
-
-
[2548.7]
-
-
[2503.7]
-
-
-
-
p2045 = r2050[3]
-
5
6
fp_2434_55_eng.vsd
17.07.13 V05.02.03
PROFIdrive sampling time
<1>
Inverted
-
-
-
-
-
-
[8060]
-
-
-
-
-
-
-
[8065]
-
-
-
[2503]
-
-
-
-
-
[2410]
-
7
Function diagram
SINAMICS S120/S150
8
- 2434 -