Siemens SINAMICS S120 Manual De Listas página 2243

Ocultar thumbs Ver también para SINAMICS S120:
Signal targets for A_DIGITAL
Signal
Meaning
A_DIGITAL.0
Digital output 8 (DI/DO 8)
A_DIGITAL.1
Digital output 9 (DI/DO 9)
A_DIGITAL.2
Digital output 10 (DI/DO 10)
A_DIGITAL.3
Digital output 11 (DI/DO 11)
A_DIGITAL.4
Digital output 12 (DI/DO 12)
A_DIGITAL.5
Digital output 13 (DI/DO 13)
A_DIGITAL.6
Digital output 14 (DI/DO 14)
A_DIGITAL.7
Digital output 15 (DI/DO 15)
A_DIGITAL.8
Reserved
A_DIGITAL.9
Reserved
A_DIGITAL.10
Reserved
A_DIGITAL.11
Reserved
A_DIGITAL.12
Reserved
A_DIGITAL.13
Reserved
A_DIGITAL.14
Reserved
A_DIGITAL.15
Reserved
<1> Used in telegrams 390 to 396.
<2> Can be set via p0728 as input (DI) or output (DO).
1
2
DO: CU_G, CU_S
PROFIdrive - A_DIGITAL interconnection
Interconnection
parameters
p0738 = r2091.0
<2>
<2>
p0739 = r2091.1
<2>
p0740 = r2091.2
<2>
p0741 = r2091.3
p0742 = r2091.4
<2>
p0743 = r2091.5
<2>
<2>
p0744 = r2091.6
<2>
p0745 = r2091.7
<3> Pre-assignment, can be freely changed.
3
4
[Function diagram]
[Function diagram]
internal status word
signal target
<3>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5
6
fp_2497_54_eng.vsd
27.06.13 V05.02.03
PROFIdrive sampling time
<1>
Inverted
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
7
8
Function diagram
- 2497 -
S120/S150/G130/G150
loading

Este manual también es adecuado para:

Sinamics s150