Siemens SINAMICS S120 Manual De Listas página 2386

Ocultar thumbs Ver también para SINAMICS S120:
Parameter value
Input signal
=1
p3291[0...2]
(0)
<1>
Activate function
p3290.0 (0) - Function 1
p3290.2 (0) - Function 2
p3290.4 (0) - Function 3
0
1
Signal source address
p3292[0...2]
<1>
Contents of data
register
<1>
Signal source data type
p3293[0...2]
<1> Index [0]: Variable signaling function 1
Index [1]: Variable signaling function 2
Index [2]: Variable signaling function 3
<2> Possible sampling times:
1.000 ms, 2.000 ms, 3.000 ms, 4.000 ms
<3> For a value of 0, the delay is disabled.
1
2
DO: HLA, SERVO
Servo control - Variable signaling function 1, 2, 3
Comparison with sign
p3290.1 (1) - Function 1
p3290.3 (0) - Function 2
p3290.5 (0) - Function 3
Threshold value
p3295[0...2]
0
1
0
1
3
4
<1>
Exceed
1
Fall below
0
<1>
Pickup delay
Dropout delay
p3297[0...2]
p3298[0...2]
<3>
5
6
fp_5301_01_eng.vsd
23.07.18 V05.02.03
p3299[0...2] (4.000 ms)
<1>
<2>
Hysteresis
p3296[0...2]
<1>
t
Output signal
r3294.0
r3294.1
Function 2
r3294.2
Function 3
<1>
7
8
Function diagram
- 5301 -
SINAMICS S120
loading

Este manual también es adecuado para:

Sinamics s150