Siemens SINAMICS S120 Manual De Listas página 2270

Ocultar thumbs Ver también para SINAMICS S120:
Slave Motor Module ready for communication
r9872.24
<1>
<1> Only with a parallel Motor Module connection and enabled Extended Functions.
1
2
DO: SERVO, VECTOR
SI Basic Functions - Monitoring functions and faults/alarms
Safety Integrated version
Monitoring clock cycle
MM
MM
CU
CU
r9870
r9880
r9770
r9780
STOP F
Safety monitoring functions
Faults/alarms
CU: F/A01600 ... 01699
MM: F/A30600 ... 30699
CU
MM
CU
MM
r9794
r9894
r9795
r9895
Cross checking list
Diagnostics for STOP F
[2804.4]
3
4
SI STOP F->A CU
p9658
SI STOP F->A MM
p9858
F01611
F30611
T
1 = Faults with response
"NONE"
Timer for
emergency
retraction
1 = Faults with response
"immediate pulse suppression"
r9772.15 (CU)
[2804.2]
r9872.15 (MM)
[2804.5]
≥1
5
6
fp_2802_54_eng.vsd
28.05.14 V05.02.03
r9780 CU/r9880 MM
0
≥1
r9772.10 (CU)
[2804.2]
r9872.10 (MM)
[2804.5]
≥1
To Safe Brake Control
[2814.1]
r9772.9 (CU)
[2804.2]
r9872.9 (MM)
[2804.5]
7
Function diagram
S120/S150/G130/G150
8
- 2802 -