Siemens SINAMICS S120 Manual De Listas página 2484

Ocultar thumbs Ver también para SINAMICS S120:
I_act abs val unsmoothed [Arms]
r0068[0]
n_act smoothed with p0045 [rpm]
<2>
r0063[1]
n_act smooth [rpm]
r0063
<1>
State of breaking
<1> Only for SERVO.
<2> Only for VECTOR.
<3> Only if p0610[M] = 12.
1
2
DO: SERVO, VECTOR
Signals and monitoring functions - Thermal motor model 3
Activate thermal motor model 3
p0612.2[M] (0)
Thermal motor model 3
Only for:
synchronous motors
<3>
Mot temp resp
Standst boost_fact
1.0000...2.0000
p0610[M] (12)
p5350[M] (2.0000)
3
4
Fault threshold
0.0...200.0 [°C]
p5391[M] (120.0)
Mot T_copper
r0632[M] [°C]
Mot T_stator
r0631[M] [°C]
2 K
Alarm threshold
Mot T_rotor
0.0...200.0 [°C]
r0633[M] [°C]
p5390[M] (110.0)
2 K
5
6
fp_8019_54_eng.vsd
31.03.20 V05.02.03
192.00 ms
≥1
Mod 3 t_stage
r5387[M] [s]
T
0
Mot_utiliz therm [%]
r0034
7
8
Function diagram
- 8019 -
S120/S150/G130/G150
loading

Este manual también es adecuado para:

Sinamics s150