Siemens SINAMICS S120 Manual De Listas página 2481

Ocultar thumbs Ver también para SINAMICS S120:
Mot temp_sensor
p0600[M]
[8018.8]
ϑ from encoder 1
1
[4704.8]
[4704.8]
11
Mot temp S_src 2 [°C]
20
p0608[0...3]
(0)
e.g. r4105 from TM120
Mot temp S_src 3 [°C]
21
p0609[0...3]
(0)
e.g. r4105 from TM120
Mot Temp S_src [°C]
p0603
10
(0)
e.g. r4105 from TM31
[8018.1]
<1> For KTY, PT100, PT1000 and PTC, the value p0606 = 0 has a different meaning:
KTY, PT100, PT1000: 0
The output of the timer is always switched out (logical 0)
PTC: 0
Delay time = 0 s
<2> The switch-in delay p0607 = 0 suppresses fault F07016.
<3> For KTY, PT100, PT1000 and "No sensor", temperature as defined in the model.
1
2
DO: SERVO, VECTOR
Signals and monitoring functions - Thermal monitoring motor
MAX
≥1
<7>
r4620[0]
r4620[1]
r4620[2]
Mot temp_sens type
p0601[M]
Temperature channel
Temp_sens type
0 = No sensor
1
2
3
1 = PTC alarm & timer
p4600[E]
p4601[E] p4602[E] p4603[E]
2 = KTY84
r4620[0]
r4620[1]
r4620[2]
3 = KTY84 & PTC <5>
Temperature channel
4 = Bimetallic NC
contact alarm &
Temp_sens type
timer (only for
1
2
temp. evaluation
via MM)
p4610[M]
p4611[M] p4612[M] p4613[M]
5 = PT100 <6>
Configuration
6 = PT1000
7 = PT1000 & PTC
0 = No sensor
<5>
10 = PTC fault
11 = PTC alarm
Evaluation across
12 = PTC alarm & timer
several temperature
channels:
20 = KTY, PT100, PT1000
10 = SME12x
30 = Bimetallic NC contact fault
31 = Bimetallic NC contact alarm
11 = BICO
32 = Bimetallic NC contact alarm &
timer
<4> p0606 does not work for alarms via p0616.
<5> Only for motors with DRIVE-CLiQ.
<6> p0601 = 5 can only be evaluated if r0192.15 = 1 and p0600 = 11; PT100 is calibrated via p0624.
<7> The assignment of temperature channels 1 ... 4 depends on the hardware used.
<8> The relevant rated response temperature (°C) depends on the temperature sensor chosen by the motor manufacturer.
3
4
Mot_temp
r0035
Mod 1/2 threshold
p0605[M]
≥1
KTY/PT1000 sensor type
(threshold not applicable for PTC)
Mod 2/sens A_thr
p0604[M]
r4620[3]
M I N
1650 Ω
4
r4620[3]
<3>
PTC
3
4
Sensor fault time
-140...20 [°C]
p4622[M] (-140)
250 °C
5
fp_8016_54_eng.vsd
31.03.20 V05.02.03
Mot temp response
0, 1, 2, 12
p0610[M] (12)
&
I_red inhibit S_src
p5388[M]
Mot temp alarm 1
(0)
p0616[M]
&
=1
r5389.8
<8>
>0
Calculation I_max red
Mod 2/sens timer
p0606[M]
I_max reduction
[6300.1] [6640.1]
<1>
<4>
T
0
&
≥1
≥1
r2135.12
≥1
p0607[M]
r2135.14
<2>
T
0
A07820 "Temperature sensor not connected"
6
7
Function diagram
S120/S150/G130/G150
48 ms
[8015.3]
[2548.2]
[2548.2]
8
- 8016 -