Siemens SINAMICS S120 Manual De Listas página 2257

Ocultar thumbs Ver también para SINAMICS S120:
From speed signals 1 [8010.8]
From speed signals 1 [8010.8]
From speed signals 2 [8011.8]
From speed signals 2 [8011.8]
From torque signals [8012.8]
From torque signals [8012.5]
<1> n_act = Smoothed speed actual value r2169 [8010.2].
1
2
DO: SERVO, VECTOR
Internal control/status words - Status word, monitoring functions 3
Bit No.
Status word, monitoring functions 3
0
1 = |n_act| < speed threshold value 3 (p2161)
1
1 = f or n comparison value reached or exceeded (p2141)
2
Reserved
3
Reserved
4
1 = Speed setpoint - actual value deviation within tolerance t_on
1 = Ramp-up/ramp-down completed
5
0 = Ramp-function generator active
6
1 = Current below the zero current threshold
7
Speed deviation model/external in tolerance
8
Reserved
9
Reserved
10
Reserved
11
1 = Torque utilization < torque threshold value 2 (p2194)
12
1 = Excitation current outside the tolerance range
13
Reserved
14
Reserved
15
Reserved
3
4
<1>
r2199.0
r2199.1
r2199.4
r2199.5
r2199.6
r2199.7
r2199.11
r2199.12
5
6
Function diagram
fp_2537_54_eng.vsd
S120/S150/G130/G150
09.11.16 V05.02.03
p0115[4]
ZSW monitoring functions 3
r2199
[8012.1]
7
8
- 2537 -