Signal targets for STW2 Standard telegram 3 (p0922 = 3)
Signal
Meaning
STW2.0
Drive data set selection DDS, bit 0
STW2.1
Drive data set selection DDS, bit 1
STW2.2
Drive data set selection DDS, bit 2
STW2.3
Drive data set selection DDS, bit 3
STW2.4
Drive data set selection DDS, bit 4
STW2.5
Reserved
STW2.6
Reserved
STW2.7
Reserved
STW2.8
Reserved
STW2.9
Reserved
STW2.10
Reserved
STW2.11
Reserved
STW2.12
Master sign-of-life, bit 0
STW2.13
Master sign-of-life, bit 1
STW2.14
Master sign-of-life, bit 2
STW2.15
Master sign-of-life, bit 3
<1> Not for TM41.
1
2
DO: TM41
Terminal Module 41 (TM41) - STW2 control word interconnection (p0922 = 3)
Interconnection
<1>
p0820[0] = r2093.0
<1>
p0821[0] = r2093.1
<1>
p0822[0] = r2093.2
<1>
p0823[0] = r2093.3
p0824[0] = r2093.4
<1>
p2045 = r2050[3]
3