Voltage
Current
V
I S5.0
X131.7
S5.0
+
<1>
AI 0
-
X131.8
+/-20 mA
+/-10 V
CU AI inv S_src
p0767[0]
CU AI absVal act
p0766[0] (0)
0
1
<1> Differential input!
In case of a ground-based input signal, the terminal X131.8 must be connected to the reference potential M.
Caution:
The voltage between an input (X131.7 or X131.8) and the grounding point must not exceed 35 V.
When the load resistor is switched in (S5.0 closed), the voltage between the input terminals must not exceed 15 V.
<2> For p0756 = 2, 3, 5 the units are mA.
For p0756 = 0, 4 the units are V.
1
2
DO: CU310-2
CU310-2 input/output terminals - Analog input (AI 0)
<2>
CU AI offset
Hardware
-20.000...20.000
smoothing
p0763[0] (0.000)
(100 µs)
+
A
+
D
(0)
CU AI T_mooth
0.0...1000.0 [ms]
p0753[0] (0.0)
0
x
-1
1
otherwise y = y(old)
3
4
<2>
<3>
CU AI type
p0756 (4)
20 mA
0
20 mA
1
<2>
<3>
CU AI U_input act
r0752[0]
0, 2
0
3
0
4 mA
4, 5
1
CU AI sim mode
CU AI sim setp
-20.000...20.000 [V]
p0797[0] (0)
p0798[0] (0.000)
CU AI enable S_src
p0769[0]
CU AI window
(1)
0.00...20.00 [%]
p0768[0] (0.00)
0
0 %
y = x if
y
|y - x| > p0768
1
<3> p0756
= 0: 0 V ... +10 V
= 2: 0 mA ... +20 mA
= 3: 4 mA ... +20 mA with monitoring
= 4: -10 V ... +10 V
= 5: -20 mA ... +20 mA
5
6
fp_2040_51_eng.vsd
11.12.12 V05.02.03
p0799[1] (4000.00 µs)
CU WireBrkThresh
0.00...20.00 [mA]
p0761[0] (2.00)
0...1000 [ms]
p0762[0] (100)
≠3
T
0
3
<2>
-11.000...11.000 [V]
-20.000...20.000
p0757[0] (0.000)
p0759[0] (10.000)
y
[%]
-1000.00...1000.00 [%]
y
p0760[0] (100.00)
2
x
x
1
-1000.00...1000.00 [%]
y
1
p0758[0] (0.00)
Scaling
r0755[0]
7
Function diagram
SINAMICS
<2>
[%]
y
x
x
2