Signal sources for ZSW1 Standard telegram 3 (p0922 = 3)
Signal
Meaning
ZSW1.0
1 = Ready for switching on
ZSW1.1
1 = Ready
ZSW1.2
1 = Operation enabled
ZSW1.3
1 = Fault present
ZSW1.4
1 = No coast down active
ZSW1.5
1 = No quick stop active
ZSW1.6
1 = Switching on inhibit active
ZSW1.7
1 = Alarm present
ZSW1.8
Reserved
ZSW1.9
1 = Control requested
ZSW1.10
Reserved
ZSW1.11
Reserved
ZSW1.12
Reserved
ZSW1.13
1 = Fault power unit thermal overload
ZSW1.14
Reserved
ZSW1.15
1 - Alarm power unit thermal overload
<1> The drive object is ready accept data.
<2> Not for TM41.
1
2
DO: TM41
Terminal Module 41 (TM41) - ZSW1 status word interconnection (p0922 = 3)
<1>
<2>
<2>
3
4
Interconnection
[Function diagram]
[Function diagram]
parameters
Internal status word
p2080[0] = r0899.0
[9680.7]
p2080[1] = r0899.1
[9680.7]
p2080[2] = r0899.2
[9680.7]
p2080[3] = r2139.3
[2548.7]
p2080[4] = r0899.4
[9680.7]
p2080[5] = r0899.5
[9680.7]
p2080[6] = r0899.6
[9680.7]
p2080[7] = r2139.7
[2548.7]
-
-
p2080[9] = r0899.9
[9680.7]
-
-
-
-
-
-
p2080[13] = r2135.13
[2548.7]
-
-
p2080[15] = r2135.15
[2548.7]
5
6
fp_9681_51_eng.vsd
19.10.11 V05.02.03
2000.00 µs
Inverted
Signal source
[9682]
-
[9682]
-
[9682]
-
[8060]
-
[9682]
-
[9682]
-
[9682]
-
[8065]
-
-
-
[9680]
-
-
-
-
-
-
-
[8021.8]
-
-
-
[8021.8]
-
7
Function diagram
SINAMICS
8
- 9681 -