Options
P51
P52
24 KW
P53
28 KW
32 KW
P54.1
P54
P54.2
P55
G20
P56
GPL
G110
P58
0% ÷ 100%
P59
0% ÷ 100%
P60
0% ÷ 60%
P61
0% ÷ 60%
P66/A
SERVICE
P66/B
P66
P66/C
P66/D
ES
IE
CONFIGURATIONS menu (the access code must be introduced)
Description
Displays the fan signal value read by the circuit board
Sets the fan reference during its normal functioning
(can be set from 60Pa to 90Pa)
Identifies the power of the boiler on which the circuit board is installed
Displays the temperature measured by the probe positioned on the cylinder
Not used
Displays the heating delivery temperature at which the boiler functions, calcu-
lated by the active controls on plant heat adjustment
The boiler functions with methane gas
The boiler functions with LPG gas
The boiler functions with G110 gas
Set the maximum power in domestic water functioning
(can be set from 0% to 100%)
Set the maximum power in environmental heating functioning
Set the minimum power in domestic water functioning
Set the minimum power in environmental heating functioning
Without external probe (optional) it defines the minimum delivery tempera-
ture.
With the external probe present it defines the minimum delivery tempera-
ture corresponding to functioning with maximum external temperature (see
graphics Fig. 1-9)
(adjustable from 35°C to 50°C)
N.B.: to continue, the parameter must be confirmed (press "D" or exit from
"P66" by pressing "C")
Without external probe (optional) it defines the maximum delivery tempera-
ture.
With the external probe present it defines the maximum delivery tempera-
ture corresponding to functioning with minimum external temperature (see
graphics Fig. 1-9) (adjustable from 50°C to 85°C)
N.B.: to continue, the parameter must be confirmed (press "D" or exit from
"P66" by pressing "C")
With the external probe present it defines at which minimum external
temperature the boiler must function at maximum delivery temperature (see
graphics Fig. 1-9)
(adjustable from -20°C to 0°C)
N.B.: to continue, the parameter must be confirmed (press "D" or exit from
"P66" by pressing "C")
With the external probe present it defines at which maximum external
temperature the boiler must function at minimum delivery temperature (see
graphics Fig.1-9)
(adjustable from 5°C to +25°C)
N.B.: to continue, the parameter must be confirmed (press "D" or exit from
"P66" by pressing "C")
170
Value set by
Default value
technician
-
-
Set in factory
during in-
spection
The same as
The same as
boiler power
boiler power
-
-
-
-
-
-
The same as
the type of
gas in use
100%
100%
0%
0%
35°C
85°C
-5°C
25°C