Stanley SC Serie Manual De Instrucciones página 92

SC Series Controllers
Configuration
Redundant Angle
Save the changes.
8.2.1.4
Update interactive menu button
Under Service Card header -> Select Tool Card -> Select Update menu button -> Select the software -> Cycle
OK -> Reboot the tool
Use this button to change the tool configuration or to update the firmware in the tool.
Change the tool configuration
Download a configuration INI file from the Internet and transfer it to a USB memory stick. Insert the USB
memory stick into the USB port. Press the UPDATE interactive menu button to open the file browse window.
Select the folder path and press the OK interactive menu button.
Change the tool firmware
Download a software BIN file from the Internet and transfer it to a USB memory stick. Insert the USB memory
stick into the USB port. Press the UPDATE interactive menu button to open the file browse window.
Select the desired BIN file and press the OK interactive menu button.
Save the changes.
8.2.2
Controller
Under Service Card -> Select Controller Card
This tab displays the controller information. Updating the controller's firmware is managed here.
8.2.2.1
About
Under Service card header -> Select Controller Card -> About
This tab displays information about the controller. These values are read only unless blank. The Model and
Serial fields can be written to once.
The About menu changes to add information about the optional fieldbus card installed such as DeviceNet,
Profibus, ProfiNet or Ethernet/IP.
92 / 1032
Tolerance
ENABLE or DISABLE the redundant angle sensor to check the primary angle
sensor's operation. This parameter is only available when a tool with a redundant
transducer is attached. When enabled the controller compares the redundant
angle sensor's signal to the primary angle snesor's signal continuously, even at
rest. If the difference in the values exceeds the Tolerance the controller stops the
tool with a shutoff code of A1 ≠A2.
Tolerance
This is the specific tolerance value for the redundant
transducer to check against the primary transducer.
Units are percentage of Max Torque of the tool. This
parameter is only available when a tool with a
redundant transducer is attached.
This is the specific tolerance value for the redundant
angle sensor to check against the primary angle
sensor. Units are defers of rotation of the tool.