Outputs
Description
*RUNDOWN
This output will be one of two selections. The selections are the User Defined Value for the
STATUS
associated status of the last fastening cycle. For example: if the last fastening cycle status
was OK, and the User Defined Value for OK is Good, then this output value is Good.
The OK User Defined Value asserts at the end of a fastening cycle when the achieved
torque and angle for the Audit step are within specified limits.
The NOK User Defined Value asserts at the end of a fastening cycle when the achieved
torque and angle for the Audit step are NOT within specified limits.
The value resets to zero (0) when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
OK: User Defined Value
NOK: User Define Value
Spindle: Type the spindle number from which the signal comes.
*RUNDOWN TASK This value indicates the task in which the last fastening cycle was performed. It asserts
when the fastening cycle is complete (after the IN CYCLE bit resets). The value resets to
zero (0) when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the signal comes.
*RUNDOWN
This is the numeric equivalent value of the torque units of the last fastening cycle. It
UNITS
asserts when the fastening cycle is complete (after the IN CYCLE bit resets). The value
resets to zero (0) when the tool is commanded to run again.
The numeric equivalent values are:
0 – NM
1 – FTLB
2 – INLB
3 – INOZ
4 – KGM
5 - KGCM
6 – NCM
7 – NDM
Size: Can be any size from 0 to 32 bytes depending on Data Type
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the signal comes.
*RUNDOWN YEAR This is the year value of the last fastening cycle date. It asserts when the fastening cycle is
complete (before the IN CYCLE bit resets). The value resets to zero (0) when the tool is
commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the signal comes.
SNUG ACHIEVED Asserts at the end of a fastening cycle if the achieved torque value exceeds the Snug
Torque value during the fastening cycle. Resets when the tool is commanded to run again.
Can also be reset with the RESET RESULTS STATUS input.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Step: Audit, Audit-1, Audut-2
Output Type: Normal, Timed, Flash
SC Series Controllers
Configuration
75 / 1032