Stanley SC Serie Manual De Instrucciones página 47

Input the yield angle value which the tool will shut off during an angle control strategy if the tool is not
reached the yield angle target.
Speed:
The velocity of the output of the tool before any Downshift Mode activates (required for any step). Units are
RPM. Must be greater than 0. Default is 9999.
Acceleration:
The rate the tool ramps up to Speed in RPM/s (revolutions per minute per second). Should be greater than
1,000 RPM/s. The default is 3,000 RPM/s.
Downshift Mode:
Selects the type of spindle inertia control toward the end of a fastening cycle.
1. Disabled:
Does not reduce the speed of the motor.
2. Manual:
Reduces the tool speed to a specific value (Downshift Speed) at a specific rate (Deceleration) when a spe-
cific torque value (Downshift Torque) is reached during the fastening cycle. Speed units are RPM, decelera-
tion units are RPM/sec, torque is in torque units.
3. ATC:
Enables the Adaptive Tightening Control algorithm to slow the tool's speed as the torque rises. The default
values can be modified for when the algorithm starts (ATC Starting Torque), when it ends (ATC Ending
Torque) and the tool speed after the algorithm ends (ATC Ending Speed). The torque units are a percent of
Target Torque. The speed values are a percent of Speed.
4. ATC+:
Enables the Adaptive Tightening Control Plus algorithm to slow the tool's speed based on a sampled torque
rate. The default values can be modified for when the algorithm starts monitoring rate (Threshold Low),
when it stops monitoring rate (Threshold High) and the tool speed after the algorithm ends (Minimum
Speed). The torque units are a percent of Target Torque. The speed values are a percent of maximum
speed of the tool.
Abort Timer:
Stops the tool when the time has elapsed from the start of the step. The value should be long enough to
complete the fastening cycle during this step.
Delay Between Steps:
The time of the tool delays before proceeding with the next step in the Task. Entered in seconds.
Power:
The maximum power available to the tool to perform the fastening cycle. Required for all steps. Units are
percent of maximum rated torque of the tool. Should not be less than 100%.
SC Series Controllers
Configuration
47 / 1032
loading

Este manual también es adecuado para:

Scn