SC Series Controllers
Configuration
Outputs
Description
* TORQUE
This output will be one of three selections. The selections are the User Defined Value for
STATUS
the associated torque status of the last fastening cycle. For example: if the last fastening
cycle's torque status was High, and the User Defined Value for High is +, then this output
value is +.
The OK User Defined Value is selected when the achieved torque for the defined step are
within specified limits.
The Low User Defined Value is selected cycle when the achieved torque for the defined
Step is below the Low Torque limit.
The High User Defined Value is selected when the achieved torque for the defined step is
above the High Torque limit.
It asserts when the fastening cycle is complete (before the IN CYCLE bit resets). The
value resets to zero (0) when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
OK: User Defined Value
Low: User Defined Value
High: User Defined Value
Step: Audit, Audit-1, Audit-2
Spindle: Type the spindle number from which the signal comes.
YELLOW LIGHT
Mimics the Yellow status lights on the tool.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the cycle status comes.
* Outputs available only on fieldbus outputs.
8.1.4
Fieldbus
The Fieldbus menu is a generic term for any of the optional fieldbus types that can be added to the SC
controllers and this tab appears only when one of those options are installed. These fieldbuses allow the
configurable SC controller to be added to end user's compatible systems as trailing devices. The types of
optional fieldbuses are DeviceNet, Ethernet/IP, Profibus, and Profinet.
8.1.4.1
DeviceNet
Under Setup Card Header -> Select DeviceNet Card
This tab appears on SC controllers only when the DeviceNet port option is installed and sets the
communications parameters for the SC controller on a DeviceNet network.
DeviceNet:
● Baudrate
● Mac ID
Baudrate
Sets the SC controller's communication rate on the DeviceNet network. Choices include:
125 K bits/s, 250 K bits/s and 500 K bits/s.
78 / 1032