Stanley SC Serie Manual De Instrucciones página 45

Bailout on High Torque:
Enable, will shut off the tool when the High Torque parameter is exceeded during any Angle Control strategy.
Disable, will shut off the tool when the Torque Bailout parameter is exceeded during any Angle Control strategy.
Requires the Torque Bailout value to be set. Should be set equal to or above High Torque. Units are the
selected torque units.
1. Torque Bailout:
The torque value at which the tool will shut off during an Angle Control strategy if the tool has not reached
target angle.
Bailout on High Angle:
Enable, will shut off the tool when the High Angle parameter is exceeded during any Torque Control strategy.
Disable, will cause the tool to stop when the Angle Bailout parameter is exceeded during any Torque Control
strategy. Requires the Angle Bailout value to be set. Should be set equal to or above High Angle. Units are
degrees of rotation.
1. Angle Bailout:
The angle value at which the tool will shut off during an Torque Control strategy if the tool has not reached
target torque.
Monitor Torque Window:
If enabled, provides a torque window during the rundown phase of the fastening cycle into which achieved
torque must pass through. This window looks back from the Snug Torque of the step over the angle interval
defined. If achieved torque is outside the window the fastening cycle is ended with the Shutoff Code of [T].
1. Upper Torque:
Defines the high torque limit for the window.
2. Lower Torque:
Defines the low torque limit for the window.
3. Upper Angle:
Defines the low angle limit for the window referenced from when the Snug Torque value.
4. Lower Angle:
Defines the high angle limit for the window referenced from when the Snug Torque value.
Monitor Torque Rate:
Provides Torque Rate Monitoring during the step between a Rate Threshold to final torque of the step.
AVERAGE will provide the average torque rate during the step. INSTANT will provide the instantaneous rate at
the step target. If the average rate is greater than the high rate (or) Lesser than the low rate (or) deviation
should be lesser than the deviation limit then the tool will end up with the shutoff code [RATE]. Only available
during Torque Control strategies. NO disables this monitoring. The shutoff code is RATE.
1. Rate Threshold:
Defines the torque at which this monitoring begins.
2. High Rate:
The maximum peak rate for an acceptable fastening cycle. If the actual rate exceeds this limit the fastening
cycle will be flagged as NOK and the RED LED on the front panel and tool illuminates.
SC Series Controllers
Configuration
45 / 1032
loading

Este manual también es adecuado para:

Scn