Stanley SC Serie Manual De Instrucciones página 40

SC Series Controllers
Configuration
8.1.1.2
Task
Under Setup card header -> Select Jobs card -> Select Job card header-> Task
Name:
Name the Task to define the operation performed (15-character maximum)
Batch count:
The required number of fastenings to complete the task.
Limit rejects:
Enables a limit on rejects for the task.
1. Reject Count
The maximum number of NOK fastening cycles allowed during this Task. The default value is 3.
Units:
Operating torque units. Task values are not recalculated on unit change.
Tool operating units:
NM, Newton Meters
FT LB, Foot Pounds
IN LB, Inch Pounds
IN OZ, Inch Ounces
KG M, Kilogram Meters
KG CM, Kilogram Centimeters
N CM, Newton Centimeters
N DM, Newton Decimeters
Efficiency:
The efficiency compensation of accessories (Example: Swivel Socket) added to the end of the tool that may
decrease the final torque of the tool. This value can be 100%-80%.
Thread Direction:
For tightening a right-hand fastener use clockwise (Cw). Use counter-clockwise (Ccw) for left-hand fasteners.
The default value is clockwise (Cw).
Threshold Torque:
The threshold at which Alpha Toolbox begins storing data. Data is not stored, or available to Alpha Toolbox,
unless Threshold Torque is exceeded during the fastening cycle. A good starting point is 20% of Target Torque.
The default value is 0.
40 / 1032
= 1 FT LB
= 1 NM
1.355818
1
1
0.7375621
12
8.850745
192
141.6119
0.1382552
0.1019716
13.82552
10.19716
135.5818
100
13.55818
10
loading

Este manual también es adecuado para: