Stanley SC Serie Manual De Instrucciones página 91

8.2.1.2
Counters
Under Service Card header -> Select Tool Card -> Counter
Each of the three counter increments at the same time after an OK Fastening cycle.
Odometer – Cannot be reset. Indicates the total number of OK Fastening cycles the attached tool has
performed over its lifetime.
PM Counter – Causes the preventive maintenance indicator to illuminate (on front panel and tool) when this
value exceeds the PM Threshold.
Trip Counter – Counts the number of OK fastening cycles between resets.
Reset- Resets the PM counter and Trip Counter.
Save the changes.
8.2.1.3
Calibration
Under Service Card header -> Select Tool Card -> Calibration
This area is used to set the calibration value(s) for the attached tool.
Nominal Cal
This is a calculated value based on the torque output of the motor, the gear ratios and efficiencies. This is a
reference value only and cannot be modified.
Torque Cal
This is the specific torque calibration value for the tool. Enter a new value after performing a lab certification.
The Torque Cal should not deviate from the Nominal Cal value by more than 20%.
Modified
A value that is changed by the controller to indicate the date and time the tool was last calibrated.
Primary Transducer
Redundant Transducer
Choose which transducer will be used as the primary transducer for control and
data collection. This parameter is only available when a tool with a redundant
transducer is attached.
ENABLE or DISABLE the redundant transducer to check the primary transducer's
operation. This parameter is only available when a tool with a redundant
transducer is attached. When enabled the controller compares the redundant
transducer's signal to the primary transducer's signal continuously, even at rest. If
the difference in the values exceeds the Tolerance the controller stops the tool
with a shutoff code of T1 ≠T2.
To calibrate a tool with a redundant transducer, first disable the redundant
transducer and select T1 as the Primary Transducer. Calibrate the tool normally.
Then select T2 as the Primary Transducer and calibrate the tool normally. Enable
the redundant transducer if required. Choose the correct Primary Transducer.
SC Series Controllers
Configuration
91 / 1032