Stanley SC Serie Manual De Instrucciones página 81

The SC controller has no default I/O on the PROFINET bus. The I/O must be assigned before a GSD XML file
can be obtained.
GSD Button
Under Setup Card header -> Select Profinet Card -> Select GSD Button
EDS interactive menu button creates a GSDML file equivalent to the Profinet I/O map created. Connect a USB
memory stick to the USB port on the bottom of the One Box controller. If the Profinet I/O map is changed, a new
GSDML file must be generated.
Save the changes.
8.1.4.4
Profibus
● Under Setup Card header -> Select Profibus Card
This Profibus menu appears on SC controllers only when the Profibus port option is installed.
This menu sets the communications parameters for the SC controller on a Profibus network.
Profibus:
● Baudrate
Sets the baud rate for the SC controller on the Profibus network.
● Auto
The baud rate is determined automatically and set to the Network baud rate as determined by the Lead-
ing device.
● Bus Address
Sets the node number of the SC controller on the Profibus network. Values can be from 0 to 126.
● Compatibility
Sets the compatibility mode of the Profibus card.
● GSD Order
Sets the order of the Inputs and Outputs as listed in the GSD file. Choices are Outputs First or Inputs
First.
● Automap
Determines whether or not the SC controller will automatically select which type of I/O modules to setup
based on the assignable I/O created in section "Faults".
If NO is selected the user must enter the I/O modules manually.
● Output Modules
Type the number of modules desired. The modules will be created. User must select the number of
BYTES or WORDS that make up each module and if it has consistency or not.
● Input Modules
Type the number of modules desired. The modules will be created. User must select the number of
BYTES or WORDS that make up each module and if it has consistency or not.
If YES is selected the SC controller will create the I/O modules. User must select if Consistency is desired or
not. NO will select without consistency, YES will select with consistency
GSD Button
● Under Setup Card header->Select Profibus Card-> GSD
SC Series Controllers
Configuration
81 / 1032
loading

Este manual también es adecuado para: