Diagnostics and troubleshooting
Use the following diagnostics and troubleshooting guide to identify, isolate, and diagnose both mechanical and
controller software related problems.
Problem
Possible
Cause
Tool cable
Tool
Calibration
Factors
Strategy
Probable Solution
Analyze the tools
fault and correct it
Charge the battery
tool
Press both
simultaneously, if still
the problem exist
service the tool
Depends upon the
System gears
depends upon the
System gears
Probable Solution Major Consideration
That Led to Solution
Replace
Physical inspection:
worn, frayed, or broken
connections or wires
Replace/Repair
Swap with known, good
operating tool
Verify/Adjust
Zero or Span Fault
Verify/Adjust
No bolt count on the Run
screen for the selected
Job/ Task
Cycle Abort set to zero
(0)
Major Considera-
To Clear/Reset from
tion That Led to
Message Condition
Solution
whenever the
Change the MFB
operator presses the
parameter to not
tool's start trigger.
require Reset Reject.
Reset Reject is
programmed.
Tool Disabled:
Faulted message
appears on display
whenever the tool
faults occurs
Statistical Limit
message appears on
display when CPK
number is greater
then the given
number
X Trend message
appears on display
when the subgroup
trend is high and low.
To Clear/Reset from
Fault Condition
Replace tool cable
Replace/Repair tool
Verify and or adjust tool
calibration factor(s) to
match calibration factor(s)
for tool. May require tool
recertification.
Create new strategy
Set higher amount on
Cycle Abort
SC Series Controllers
Troubleshooting
125 / 1032