Stanley SC Serie Manual De Instrucciones página 41

Statistical Torque:
The torque level required to be exceeded before the fastening cycle data is included into Statistics or sent via a
network protocol. The default value is 0.
Disassembly Speed:
The speed of the tool during (Reverse) operation in RPM (revolutions per minute). The default value is 9999. To
limit the speed of the tool reduce this parameter to a value less than the maximum speed of the tool.
Disassembly Acceleration:
The rate at which the tool gets to Disassembly Speed in RPM/s (revolutions per minute per second). The default
value is 3,000.
Cycle Lock-Out:
This is a timer, in seconds, that activates after the tool has reached its target. While active, the tool is disabled.
Torque Rate:
This section sets values used in determining fastening cycle torque rate used in the Rate Control or Yield
Control strategies.
1. Torque Average
Number of Torque samples averaged for the Rate calculation. Calculates a running average from torque
samples taken every millisecond. A higher number gives a smoother Rate. The default value is 10 msec.
2. Angle Interval
Used to calculate the Torque vs. Angle Rate. Larger intervals may give a smoother Rate. The default value
is 20°.
Modified:
A value that is changed by the controller to indicate the date and time parameter values were last changed in
this Task or associated Steps.
Blind Rivet specific parameters are shown below:
Threshold Force:
The force level during the fastening cycle when the In-Cycle output transitions high. Data is not stored, or
available to Alpha Toolbox, unless Threshold force is exceeded during the fastening cycle. The default value is
0.
Statistical Force:
The force level required to be exceeded before the fastening cycle data is included into Statistics or sent via a
network protocol. The default value is 0.
SC Series Controllers
Configuration
41 / 1032
loading

Este manual también es adecuado para:

Scn