Stanley SC Serie Manual De Instrucciones página 70

SC Series Controllers
Configuration
Outputs
Description
The OK User Defined Value is selected when the achieved angle for the defined Step are
within specified limits.
The Low User Defined Value is selected when the achieved angle for the defined Step is
below the Low Angle limit.
The High User Defined Value is selected when the achieved angle, for the defined Step, is
above the High Angle limit.
It asserts when the fastening cycle is complete (before the IN CYCLE bit resets). The
value resets to zero (0) when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Step: Audit, Audit-1, Audit-2
OK: User Defined Value
Low: User Defined Value
High: User Defined Value
Spindle: Type the spindle number from which the angle status comes.
*BOLT
This output is the value of the active accumulated bolt count. As the bolt count changes so
does this output.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the bolt status comes.
*CONSTANT
This value is defined by the end user in the Constant parameter. It asserts when the
fastening cycle is complete (after the IN CYCLE bit resets). The value resets to zero (0)
when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Constant: Type the value of the constant required
CYCLE ABORTED Asserts when the controller shuts the tool off due to a fault or if the Stop/Abort within Limits
parameter is used and the fastening cycle has a shutoff code of ABORT. Resets when the
tool is commanded to run again. Can also be reset with the RESET RESULTS STATUS
input.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the abort status comes.
CYCLE NOK
Asserts at the end of a fastening cycle when the achieved torque and/or angle for the Audit
step are NOT within specified limits. Also asserts when the Stop/Abort within Limits
parameter is set to Yes and the tool is stopped or aborted within limits. Resets when the
tool is commanded to run again. Can also be reset with the RESET RESULTS STATUS
input.
Size: 1 bit
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the cycle status comes.
CYCLE OK
Asserts at the end of a fastening cycle when the achieved torque and angle for the Audit
step are within specified limits. Will not assert if the Stop/Abort within Limits parameter is
set to Yes and the tool is stopped or aborted within limits. Resets when the tool is
commanded to run again. Can also be reset with the RESET RESULTS STATUS input.