en
50 | SL 6xx | Manual mode (normal operation)
Step
5. Braking force measurement:
¶
Slowly and steadily depress brake
pedal until maximum braking force
(slip) is attained.
¶
Release brake pedal again.
i
Shut-off criteria:
$
Wheel lock-up (slip monitoring).
$
Motorcycle drift (touch roller no
longer pressed).
$
Maximum braking force (slip) not
attained on braking and braking
action remains at rolling resistance
level for more than six seconds.
6. End of measurement for tester
without motor brake.
¶
Start of measurement
¶
Drive motorcycle off set of rollers.
|
1 691 706 020
2012-12-11
Remote control
Result / Display
The current values are displayed on the screen:
$
Braking force (F)
$
Pedal force (PD)
$
Braking factor (Z)
Peak value display (approx. 5 seconds).
"
The measured values can now be stored.
"
Braking force measurement over.
+
+
Beissbarth GmbH