Select empty signal

The empty signal describes the type of empty signal.
The "Empty signal contact" selection defines whether or not the empty signal is triggered
with an open contact or closed contact.
A suitable suction pipe must be connected to the empty signal input on the
pump on terminals 25, 26 and 27
(suction lance)' on page 56.
The following should be noted here:
– Connect zero-potential contact to pulse input and GND.
– Do not connect any external voltages!
– Minimum switch-on and switch-off times = 15 ms.
Fig. 56: Configuration: Empty signal acknowledgement
Factory setting: Auto acknowledge (acknowledge automatically)
Selection of the [Configuration menu] - [Select empty signal]:
1.
[Main menu] :
2.
[Configuration menu] :
3.
Use the scrollbar to scroll to the [Select empty signal] menu option.
4.
[Select empty signal] - select.
5.
If required, 'empty message contact' : 'closed contact = select empty signal'
ð After selecting this, a check mark
6.
[Press the Next button]
ð Screen changes to the acknowledgement query of the 'empty signal' .
7.
Select the required option:
The following options can be selected:
Ä Chapter 7.10.8.1 'Acknowledge automatically: ' on page 99
n
Ä Chapter 7.10.8.2 'Acknowledge manually: ' on page 100
n
8.
Pressing the
ð The screen switches to the overview: [Configuration menu].
9.
Pressing the
10. Pressing the
417102276 Rev. 3-01.2019
Ä Chapter 7.7 'Main menu' on page 67
Ä Chapter 7.10 'Overview - Configuration' on page 87
.
button saves the setting.
button returns to the [Main menu].
button returns to the [Operating display].
98
Ä Chapter 6.4.9 '[Level] Level monitoring
is set in the selection field.