Step three: Set the metering rate/capacity in litres
The following screens show example displays for a pump with capacity of
11 l/h. Specifications and information shown will differ for other pump sizes.
Fig. 36: Set the metering rate/capacity in litres
1.
In the [Operating display] press the displayed 'capacity in litres' .
ð The screen switches to the screen for setting the 'capacity in litres' .
2.
'Set the decimal places of the capacity in litres' using the scroll bar.
3.
Select the field for entering the value after the decimal point.
ð The colour changes to dark blue, which indicates that the field is ready for the
entry.
4.
'Set decimal places of the capacity in litres' using the scrollbar.
5.
Pressing the
ð The operating screen shows the newly set 'capacity in litres' .
7.9.3

Operating mode [Pulse]

There are two setting options in the Pulse operating mode:
– Concentration:
Ä Chapter 7.9.3.1 '[Operating mode] [Pulse] - Concentration' on page 78
– Quantity:
Ä Chapter 7.9.3.2 '[Operating mode] [Pulse] - Quantity' on page 80
The following should be noted here:
– Do not connect any external voltages!
– Connect zero-potential contact to pulse input and GND.
– Minimum switch-on and switch-off times = 15 ms.
To access the setting, press and hold the 'capacity in litres' shown on the
display, for around 3 seconds.
button saves and returns to the [Operating display].