Control / software
7.2
Start screen
Fig. 18: Start screen
1
Manufacturer's logo
2
Pump size (litre output)
3
Materials of the pump components
4
Specific pump specifications
As the pump has a hardware detection feature whose software checks the devices
connected, the display may last for more than 5 seconds under certain circumstances until
the check has been completed. The screen then changes to the operating mode.
The menu can be used to call up the 'Info' screen at any time:
Ä Chapter 7.13 'Info' on page 122.
7.3
Using the touchscreen
This chapter describes the buttons, symbols and input options used on the
touchscreen.
Some of the operating elements shown on the touchscreen can be selected by
touch.
In the following chapter, the instructions for the settings are indicated by a hand
or
The
previous menu level.
DANGER!
The touchscreen can be damaged if it is used incorrectly.
The touchscreen is designed to be operated by finger.
Do NOT use any sharp objects (for instance, tools, pencils, pens, etc.)
to operate the touchscreen!
417102276 Rev. 3-01.2019
in the diagrams.
view marks an action step. The
58
When switching on the pump, the following is
displayed for approx. five seconds:
n
Specific pump key
n
Specific production code
n
Version of the software being used
n
Supply voltage of the pump
n
Materials used for pump head, diaphragm,
valves and valve ball
5
Specific pump key
6
Software versions: System/motor/Bluetooth
7
Supply voltage of the pump
8
Material of the valve ball
view marks the way back to the