Control / software
[Calibration] - start:
1.
[Main menu] :
2.
[Configuration menu] :
3.
Scroll up to [Calibration] using the scrollbar along the right edge of the screen.
4.
[Calibration] - select
ð The screen changes to [Calibration].
5.
'Press Start' .
ð Screen changes to the 'Calibration step 1' .
6.
Calibration step 1 runs automatically.
7.
Screen side 'Calibration step 1' is launched.
Enter the quantity in litres (before the decimal point) using the scrollbar.
8.
Select the quantity in millilitres after the decimal point.
9.
Enter the quantity in millilitres (after the decimal point) using the scrollbar.
10. Press the Next
ð Screen changes to the 'Calibration step 2' .
11.
'Calibration step 2' runs automatically.
12. Screen side 'Calibration step 2' is launched.
Enter the quantity in litres (before the decimal point) using the scrollbar.
13. Select the quantity in millilitres after the decimal point.
14. Enter the quantity in millilitres (after the decimal point) using the scrollbar.
15. [ Press the Next button]
ð The setting is saved, and the screen switches back to the operation screen.
417102276 Rev. 3-01.2019
Ä Chapter 7.7 'Main menu' on page 67
Ä Chapter 7.10 'Overview - Configuration' on page 87
In this step the calibration runs automatically.
The pump completes a specified pump-specific number of strokes and
counters these down to 0.
The elapsed oval gear meter pulses (OGM) are counted at the same
time. The pump stops after the strokes elapse.
button.
The calibration sequence runs again automatically in this step.
.