14.5

Electrical data

Name
Supply voltage [V / Hz]
Motor power [W]
IP Code
Appliance class
Level, external release, batch
Inputs:
Pulse, standard signal (0/4-20 mA)
Minimum pulse duration (On/Off)
Alarm (relay contact)
Outputs:
Stroke signal (transistor)
External power supply
Permissible cables:
Permissible external cable diameters for connecting the inputs/outputs:
AD Ø = 5.1-5.7 mm. LIYY 4 x 0.5; LIYY 5 x 0.34; LYCY 2 x 0.34
Permissible cables: Ölflex 4 x 0.5
The IP65 is applicable only when the specified cable is being used.
14.6

Tightening torques

NOTICE!
It is essential that the tightening torques given below are observed, firstly to
ensure the leak-tightness of the system and secondly to ensure the integrity of
the thread.
The tightening torques of the metering head screws are given on an adhesive
label that is affixed to the pump head.
Tightening torque of the suction/pressure valves:
Pump head size
Tightening torque
Tightening torque of the metering head screws:
Pump head size
Tightening torque
5 l/h and 11 l/h
2 ± 0.2 Nm
5 l/h and 11 l/h
3,75 ± 0.25 Nm
173
Technical specifications
Type
Type
Type
00510X
01110S
03003M
100 - 240 ±10% / 50/60
30
IP65
II
max. 24 V DC / 6 mA
max. 25 mA (approx. 50 Ohm)
15 mS
230 V, AC/DC, 3 A
max. 24 V, DC, 200 mA
5 V, max. 100 mA
5 l/h and 11 l/h
2,8 ± 0.2 Nm
5 l/h and 11 l/h
6 ± 0.25 Nm
417102276 Rev. 3-01.2019
Type
Type
05010M
12003M
50
5 l/h and 11 l/h
4 ± 0.2 Nm
5 l/h and 11 l/h
6 ± 0.25 Nm