Control / software

7.10.15 Diaphragm brakeage

An automatic monitoring of the pump diaphragm can be switched on or off under
'Diaphragm brakeage' .
Requirements:
n
This function can only be used when a pump head of 30 l/h, 50 l/h or 120 l/h size is
installed on the pump with the respective diaphragm protection sensor.
n
Select the corresponding sensor for diaphragm breakage
12.2.2.3 'Replacement part module: Pump head 30 l/h and 50 l/h' on page 162, pos. 9
or
Ä Chapter 12.2.2.4 'Replacement part module: Pump head 120 l/h' on page 163,
pos. 11 and install.
Electric connection - Sensor for diaphragm breakage
Switch on monitoring for diaphragm breakage:
Fig. 75: Switch on monitoring for diaphragm breakage
Factory setting: Monitoring for diaphragm breakage switched off
1.
[Call up Main menu] :
2.
[Select Configuration] :
3.
Use the scrollbar to scroll to the [Diaphragm brakeage] menu option.
4.
[Select Diaphragm brakeage] .
ð Screen switches to the query 'with diaphragm breakage.' .
5.
If required, 'select with diaphragm breakage.' .
6.
Pressing the
ð The screen switches to the overview: [Configuration].
7.
By pressing the
8.
By pressing the
417102276 Rev. 3-01.2019
The electric connection is done on the main board
Ä Chapter 6.4.7 '[Diaphragm] Diaphragm breakage monitoring ' on page 53
The connections are as follows:
14 = GND
15 = Diaphragm
16 = 5 Volt
17 = Anode
Ä Chapter 7.7 'Main menu' on page 67
Ä Chapter 7.10 'Overview - Configuration' on page 87
button saves the setting.
button, you can return to the [Main menu].
button, you can return to the [operating display].