Electrical Connection - BestFor BISTROT 433 Manual De Instruccion

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

ELECTRICAL CONNECTION:

The electrical connection must be made only by qualified personnel. It must be in compliance with
CEI requirements and specifications.
The unit must be connected to the mains only if between it and the mains there is an omnipolar
switch with at least 3 mm of opening between contacts for each pole. This must be in an easily
accessible position near the oven.
The available connections and the procedure for replacing the cable, if necessary, are described
below.
Once the electrical connections have been made, close the
terminal block cover as indicated in the figure below.
The connection cable must be at least type H07 RN-F. Fixed connections require the use of
conduits which must comply with standards.
• The figure to the side shows the connection
terminal block of the oven. Fasten the cable in
the appropriate cable terminal and proceed
with the electrical wiring.
The wiring diagram below shows the possible
connections provided for the oven. According to
the power supply voltage, wire the oven by
installing the
positions indicated. Tighten the screws firmly to
prevent dangerous overheating.
Bistrot/Gourmet Series Ovens– Page 30
appropriate jumpers in the
400V ~ 3PH + N + PE
1
2
3
4
5
L1
L2
L3
N
230V ~ 1PH + N + PE
1
2
3
4
5
L
N
400V ~ 2PH + N + PE
1
2
3
4
5
N
L1
L2
230V ~ 3PH + PE
1
2
3
4
5
L1
L2
L3
6
7
6
7
6
7
6
7