PASO 19
SuperFINDA sensor calibration info
Muy bien. Has calibrado tu sensor de filamento IR. Ahora, podemos pasar a calibrar
el sensor SuperFINDA dentro del selector en la unidad MMU.
In the next step, we will adjust the sensor's position and check if it detects the
filament correctly.
It is EXTREMELY important that both the IR filament sensor and the SuperFINDA
sensor work reliably and provide accurate readings. Otherwise, you will have
trouble with the device.
There is an inspection window on the side of the selector where you can observe
the SuperFINDA's position. It is a good starting point to line up the bottom of the
SuperFINDA probe with the top of the inspection window when looking from the
selector motor side.
If there is a filament in the selector, the steel ball is risen and should be detected by
the SuperFINDA sensor. The distance between the ball and the sensor is what must
be perfectly calibrated.