MMU Filament sensor calibration
When the Gearbox Alignment is complete, you should be prompted to continue to
the filament sensor calibration.
There should be no filament inside the extruder before the calibration process
starts.
Make sure the idler lock (swivel) is closed.
During the filament sensor calibration, you will need to use a short piece of
filament. Prepare a filament and select Continue.
Don't insert the filament before being prompted to do so!
Once prompted to, insert the filament.
After successfully calibrating the filament sensor, remove the filament from the
extruder.
PASO 16
Footer adjustment
Turning on the MMU unit automatically displays the filament sensor and Finda
sensor information on the status bar on the display. If for some reason this
information is not displayed or you want to adjust the order, proceed as follows.
On the printer, visit the Settings > User Interface > Footer.
Make sure there is Filament sensor (FSensor) selected in any of the fields.
Make sure there is SuperFINDA sensor (Finda) selected in any of the fields.
You will see the respective symbols and sensor values displayed on the bottom of
the screen.
Los valores de los sensores también se muestran en el menú Info > Info Sensor.