9. Faults/error messages/remedy

All work on electronic components may
only be carried out by skilled
electricians.
If a fault cannot be remedied by the remedial measures, consult the Pontos Service Department.
Fault
Little saving / too much drinking water feed
No process water supply
Odour / poor process water quality
Constant start-up of the pressure pump
Noises
Error message in the system display
A: Little saving / too much drinking water feed
possible cause
Run-in period active
Submersible pump 1 or 2 does
not transport any water (error
message run-time error P1/P2)
Water loss at inlet filter into the
overflow
Leak, feed valve / filter
backflush valve
Sensor malfunction
Version 2.5
Check
Green LED on display flashes
Function check of the
submersible pumps in manual
operation
Visual inspection:
Submersible pump in the
water?
Submersible pump blocked?
Hoses blocked?
Filter strainer blocked?
Ball valve VA1.1 does not
close
Visual inspection:
At drinking water / rainwater
inlet, Stage 3
At the filter backwash
nozzle, Stage 1
Comparison of the display on
the controller with the actual
state of the system.
Operating Manual AquaCycle 2500
Chapter
A
B
C
D
E
F
Remedy
Open pumps
Remove blockage, replace
hose if necessary
Actuate filter backflush in
manual operation
Remove filter strainer if
necessary, and clean it
manually
Check ball valve VA1.1
Multiple actuation of the
leaking valve in manual
operation
Clean if necessary
see chapter 7.6