Warning!
Contact with dirty water
can be a health hazard.
Wear suitable
protective gloves
when carrying out
work that brings you
into contact with the
waste water.
Danger!
Potentially lethal mains
voltage.
Carry out all work on
the system only with
the electrical power
switched off. De-
energise the system
before opening the
service door – switch
off the main switch
and unplug the
mains plug!
Make sure that the
supply voltage
cannot be switched
back on again
accidentally.
Version 1.3
Assembly Manual AquaCycle 2500
Electrical connection
Electrical systems must conform to the general
set-up regulations IEC 364/VDE 0100. Sockets
must have earth terminals.
The electrical mains (230 V~/50 HZ alternating
voltage) to which the water recycling system is
connected must have a 30 mA fault current
protector (residual current circuit breaker) as
demanded by DIN EN 60335-2-41/VDE 0700.
Consult a specialist electrician if necessary.
If the electrical connecting cable is damaged,
replace it with a H05RN-F3G 1.5mm² cable
with a protective contact plug IP44 (with
protective splash collar) as specified in
DIN VDE 0620 (2010).
Note!
In the event of a power
failure, the water
recycling system is not
ready for operation, and
downstream applications
cannot be supplied.
Caution!
UV radiation can cause
skin and eye damage
Work on the UV lamp
may only be carried
out by a specialist.
EN 9