6.3.1. "Off" mode
Description
If necessary, the system can be set to "off"
mode.
After the system has been switched on for the
first time, the controller is in "off" mode (as-
delivered state).
In this mode the system is inactive, i.e.
absolutely no actuators are set.
The controller must then be set to one of the
other modes manually.
Setting
Select mode of operation (see chapter 6.3)
Select
Acknowledge
Return to main page
Version 2.5
Operating Manual AquaCycle 2500
6.3.2. "Run-in period" mode
Description
During the run-in period, it is ensured that as
much grey water as possible flows through
tanks B1 and B2, and flows into the sewer from
B2 via the overflow. During this time, the tank
B3 is filled via the rainwater or drinking water
feed independently of B1 and B2.
The micro-organisms required for the
subsequent water treatment form during the
run-in period. This process takes between 14
and 30 days. When this adjustable period has
elapsed, the system automatically goes into
Automatic mode.
The submersible pump P2 and the UV
reactor are deactivated during the entire
period. Also, no sedimentation or tank cleaning
takes places during the run-in period.
If the menu point is actuated again during
the run-in period, the time starts again from the
beginning.
If there is a power failure during the run-in
period, the controller continues the run-in
period after the power supply is restored. If the
duration of the power failure exceeds the
adjustable time, the run-in period starts
counting again from the beginning.
Setting
Select mode of operation (see chapter 6.3)
Select
Acknowledge
Return to main page
EN 23