ORMED.DJO ARTROMOT-E2 Manual De Operación página 79

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 134
10. Place the ARTROMOT®-E2 - legs first
- on the bottom of the box. The mark-
ings on the bottom of the box indicate
the correct position.
11. Then put the enclosed polystyrene
block on the chair, observing the cut-
outs in the block.
12. Put the programming unit (15) in
the supplied box. Place the motion
element, the armrest and the power
cord in the respective cut-outs in the
polystyrene block of the package.
13. Then close the box.
Reverse the above steps to reassemble
the device after transport.
m Warning!
Shock hazard—
Allow the ARTROMOT®-E2 to reach
room temperature before use. If the de-
vice has been transported at tempera-
tures below 0 °C (32°F), leave it to dry
at room temperature for about 2 hours,
until any condensation has disappeared.
6.3.2 ARTROMOT®-E2 compact
The following operating steps must be
completed before transporting the
ARTROMOT®-E2 compact:
1. Activate the "transport setting" func-
tion
in the menu (see also 5.3)
and start the ARTROMOT®-E2 compact.
2. Turn off the ARTROMOT®-E2 compact
power switch (19).
3. Remove the power cord (18) and
disconnect the motion element (9) and
the programming unit (16).
4. Remove pin (26) on the underside and
take off the upper arm support.
5. Remove pin (5) and take off the
swiveling mechanism of the upper arm
support. Set the guide of the upper
arm support to the transport setting
(parallel with motor A).
6. Grasping the motion element at the
bracket (27) for adjustment of the posi-
tioning angle, open the locking screw
(1) and pull out the motion element.
7. Open the locking screw for adjustment
of the elbow angle adjustment (2) and
separate the oval tube from the mo-
tion element.
8. Open locking screw (24) on the un-
derside of the stand, then remove the
column with the electronics box from
the star-shaped stand.
9. Disassemble the stand by loosening
the five legs with the special tool sup-
plied and remove them.
10. Unscrew the locking screw (7) from
motor B (12), remove the entire
forearm support including the slider
(4) and the hand support (13 + 14).
Afterwards screw the locking screw (7)
back into motor B.
11. Only use the original shipping box
for transporting the device. Ormed
GmbH & Co. KG cannot be held liable
for transport damage, if the device was
not shipped in its original shipping
box.
12. Put the programming unit (15) in the
supplied box, using sufficient padding.
79
Tabla de contenido
loading

Este manual también es adecuado para:

Artromot-e2 compact

Tabla de contenido