Operating Manual X-zone Com - Assembly and Initial Operation
You may observe X-zone Com's charging progress via a display (see Ch. 6.4).
1. Battery exhausted (X-zone Com automatically switches off)
2. When the battery is connected to the charger, the symbol indicates overheating and
a temporary stop of charging. When the temperature drop, the charging will be
continued.
Battery charge 100%
4.2.2 Inserting the SIM card
To send e-mail and text messages with X-zone Com, the internal modem must have an SIM card.
To use the GSM modem, customer M2M SIM cards that are suitable for data and text (SMS) commu-
nication are necessary. Customers should obtain contracts with providers that provide the required
data volume and sufficient number of text messages. SIM cards that are also suitable for voice com-
munication (also applies to twin cards) or that are mainly intended for use with smartphones, tablets or
USB/GSM sticks, should first be activated and tested using an appropriate smartphone/tablet/USB
GSM stick. Services such as forwarding of voice services or similar should be disabled. The SIM card
can be used only in X-zone Com's GSM modem after the activation/setting is completed.
WARNING
Explosion hazard
Never connect the power supply unit to the mains inside the ex
zone when charging X-zone Com.
NOTE
Please fully recharge the battery at least once every six
months to avoid exhaustive discharge and damage to the bat-
tery.
Store X-zone Com outside the explosion exposed area in off
modus keeping it connected to the power supply unit.
WARNING
Explosion hazard
Do not open the product housing inside an ex atmosphere!
Insert or remove SIM cards only in safe non-explosive atmos-
pheres.