5.7
Deleting the IP gateway from the control panel (optional)
1.
Press the
button.
2.
Enter the 4-digit PIN code (User).
3.
Press the
button.
4.
Select the program mode "5. COMMS". The display shows "5-1 COMMS SETUP".
5.
Press the
button. The display shows "Input (01-12) Device NO.".
6.
Enter the device number (0-12). Make sure that no other device is already linked to the channel.
7.
Press the
button.
8.
Select the program mode ":4 DEVICE REMOVE". The display shows "SELECT YES>*/ NO>#".
9.
Press the
button.
5.8
Connection terminal block (optional)
1
Hardwired zone connections (closed contacts)
2
Hardwired zone connections (volt-free contacts)
To access the connection terminal block, first put the system into test mode (refer to the section "Test mode (TEST MODE)".
1.
Set jumper link P1 to the off position.
2.
Switch off the power supply to the power adaptor.
3.
Remove the control panel from the wall bracket.
4.
Disconnect the power adaptor from the control panel.
5.
Remove the battery cover.
6.
Remove and disconnect the backup battery.
7.
Wire the connections to the terminals as required.
8.
Connect and install the backup battery.
9.
Install the battery cover.
10.
Connect the power adaptor to the control panel.
11.
Switch on the power supply to the power adaptor.
12.
Install the control panel to the wall bracket.
13.
Press the
button to exit test mode.
The signaling contacts on all hardwired alarm and tamper zones must be volt free. i.e. they must only open and close and not
apply any self-generated voltage across the contacts. The contacts on zones 33, 34, 35 and the tamper circuit must be normally
closed. An alarm will be triggered when the contacts open. On zones 33, 34 and 35, additional door/window contact detectors
can be hardwired to these terminals. The contacts on zone 36 must be normally open. An alarm will be triggered when the
contacts close.
Note: Jumper link P51 must be normally in the off position. Set jumper link P51 to the on position only if the hardwired tamper
circuit is used.
5.9
Backward compatibility (security devices)
Earlier versions of 868MHz PIR movement detectors, door/window contact detectors, remote controls and remote keypads
devices are also compatible with the system. If you upgrade an existing 868MHz wireless security system, you can use the same
security devices by simply linking the security device to the GlobalGuard system.