10 Technical Data - Honeywell FRIEDLAND FGGK Serie Manual De Instrucciones

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 134
The PIR movement detector does
not detect any movement to
activate the alarm.
The door/window contact
detector does not work.
The door/window contact
detector gives a false alarm.
The indicator on the
door/window contact is on when
a door or window is opened.

10 Technical data

Control panel
Radio frequency
Communication range
Dimensions (LxWxD)
Siren
Remote control
Radio frequency
Communication range
Dimensions (LxWxD)
Battery life
IP gateway
Radio frequency
Communication range
Dimensions (LxWxD)
Door/window contact detector
Radio frequency
Communication range
Dimensions (LxWxD)
Battery life
PIR movement detector
Radio frequency
Communication range
Detection range
Dimensions (LxWxD)
Battery life
If the PIR movement detector has already detected movement in the last 2 minutes,
wait for another 2 minutes before moving in front of the detector. The PIR movement
detector goes to sleep for 2 minutes to conserve battery power after each time
movement is detected.
Make sure that the magnet is positioned correctly in relation to the detector, with a gap
of less than 10 mm between the magnet and the detector.
Make sure that the batteries are installed with correct polarity.
Make sure that the battery holder connections make good contact with the batteries
and the circuit board.
Make sure that the ID code of the detector is learned for a particular zone.
If an additional door/window contact detector is connected:
1. Make sure that both contacts are closed.
2. Make sure that the additional contact is correctly wired and that switch SW3 of the
detector is set to "INT./EXT.".
Make sure that the detector is installed within effective radio range of the control panel
and away from metal objects.
Make sure that the magnet is positioned correctly in relation to the detector, with a gap
of less than 10 mm between the magnet and the detector.
The tamper switch below the battery cover is not activated. Make sure that the battery
cover is installed correctly.
Low battery. Replace the battery.
868 MHz / 433 MHz
868 MHz: 125 m (in open space) / 433 MHz: 50 m (in open space)
215 x 215 x 47 mm
95 dB (Piezo)
868 MHz
150 m (in open space)
65 x 36 x 13 mm
> 1 year
868 MHz
150 m (in open space)
34.5 x 176.5 x 124.8 mm
868 MHz
150 m (in open space)
100 x 29 x 15 mm
> 1 year
868 MHz
150 m (in open space)
12 m at 110°
94 x 57 x 43 mm
> 1 year
30

Solución de problemas

loading

Este manual también es adecuado para:

Friedland hisk1 serie