6.2.3.1

Learning the security detector (LEARNING ID)

The control panel can learn up to 32 wireless 868MHz door/window contact detectors or PIR movement detector detectors.
The control panel can learn up to 4 wired security detectors.
1.
Press the tamper switch on the security detector.
2.
After 2 seconds, press the tamper switch on the security detector again to confirm the ID code.
Note: If the confirmation signal is not received within 15 seconds, the control panel will emit one long beep and exit learn
mode.
Note: If the security detector has already been linked, the control panel will emit one long beep.
Message
LEARNING OK
TIME OUT
ID DUPLICATE
6.2.3.2

Location (LOCATION)

You can set the location for the security detector.
6.2.3.3

Model type (MODEL TYPE)

You can set the model type for the security detector.
6.2.3.4

Security type (SECURITY TYPE)

You can set the security type for the security detector.
Security type
INTRUDER
24 HR INTRUDER
FIRE
TEST
PANIC/PA
Default settings
Item
Message
LEARNING ID
---
WIRED ZONE
OFF
LOCATION
NONE
MODEL TYPE
NONE
SECURITY TYPE
INTRUDER
CHIME MODE
OFF
PART-ARM-I
OFF
PART-ARM-II
OFF
DETECTOR STATUS
OFF
DETECTOR REMOVE
---
SIREN AT TRIGGER
ON
Zones 1-2
ENTRY DELAY
Zones 3-36
The ID code was learned by the control panel successfully.
If you do not press the tamper switch on the security detector within 60 seconds,
The same ID code was learned by the control panel beforehand.
Standard intruder monitoring with arming functions.
24-hour monitoring of areas requiring continuous security protection, even when the
system is disarmed. If a security detector is activated, a full-alarm condition will be
24-hour monitoring of all fire/smoke detectors connected to the system. If a security
detector is activated, a full-alarm condition will be initiated immediately.
When the system is armed, any detector setup will not initiate an alarm, but will generate
an event in the event log. All email contacts in the online account will receive an email
alert. All mobile devices running the app will be alerted.
The same ID code was learned by the control panel beforehand.
20
DELAYED 030 SECONDS
INSTANT 030 SECONDS
Meaning
a time-out will occur.
Function
initiated immediately.