POWER SUPPLY
This device should only be used with a power supply which appears below:
DENTSPLY
Reorder#
Model
Voltage
644031
GTM3T48-12-1200D (US)
120v
644029
GTM3T48-12-1200D-3 (EU)
230v
644036
GTM3T48-12-1200D-4 (UK)
240v
644030
GTM348-12-1200D (Japan)
100v
TECHNICAL DATA
Model 200
AC Input Rating: Reorder #644025: 120v
Reorder #644026: 230v EU
Reorder #644027: 240v UK
Reorder #644028: 100v
DC Output Rating:
12vDC, 1200ma
Protection from electric shock:
Type BF Applied Part
IEC Equipment Class II/Internally Powered
Protection against ingress of water:
(Ordinary Equipment) IXPO
Operation Mode:
Continuous operation with intermittent loading: (1 min./5 min. = 1 min. On/5 min. Off)
Operating Environment:
NOTE: Equipment not suitable for use in the presence of a
flammable anesthetic mixture with air or with nitrous oxide
Temperature:
50°-86°F (10°-30°C)
Relative Humidity:
10% to 75% (non-condensing)
Atmospheric Pressure:
700 to 1060 hPa
Transport and Storage Conditions:
Temperature:
14°-140°F (-10°- +60°C)
Relative Humidity:
10% to 100%
Atmospheric Pressure:
500 to 1060 hPa
Dimensions:
Charging Base Height:
4.8 inches (12.2 cm)
(with handpiece):
5.9 inches (15 cm)
Charging Base Width:
2.9 inches (7.4 cm)
Charging Base Length:
7.2 inches (18.3 cm)
Charging Base Weight:
12 ounces (0.34 kg)
power supply plug length:
72 inches (183 cm)
Handpiece Length (w/o probe): 6.6 inches (16.8 cm)
Handpiece Width:
1.4 inches (3.5 cm)
Handpiece Height:
5.0 inches (12.7cm)
Handpiece Weight (w/o probe): 8.0 ounces (0.23 kg)
Complies with the following Directives/Standards:
93/42/EEC
MDD
Directive
IEC 601-1
1988 – Medical Electrical Equipment (General Requirements for Safety)
IEC 601-1 Am.1
1991 – Amendment 1 to IEC 601-1
IEC 601-1 Am.2
1995 – Amendment 2 to IEC 601-1
EN 60601-1
1993 – Medical Electrical Equipment (General Requirements for safety) Amendments 1-13.
EN 60601-1-2
1993 – Medical Electrical Equipment Part 1: General requirements for safety 2: Collateral standard:
Electromagnetic compatibility – Requirements and tests
CAN/CSA C22.2
M90-Medical Electrical Equipment Part 1: General requirements for safety (Amendment 1 and 2)
No.601.1-M90
UL 2601-1
2nd Edition – Medical Electrical Equipment: Part 1: General Requirements for safety
IEC/EN 60825-1
Laser Testing Edition 1.2:2001
8
GLOSSARY OF SYMBOLS
Attention, Consult Accompanying Documents
Alternating Current
Direct Current and Alternating Current
Type BF Applied Part
Lamp On/Off
ACCESSORIES AND SPARE PARTS
Description
Reorder No.
Light Shield
644804
Replacement SmartLite iQ2 Battery
644033
Curing Probe: 12 x 8mm Tapered 60° angle
644718
SmartLite iQ2 Unit Power Supply 120v
644031
SmartLite iQ2 Unit Power Supply 100v Japan
644030
SmartLite iQ2 Unit Power Supply 230v EU plug
644029
SmartLite iQ2 Unit Power Supply 240v UK plug
644036
SmartLite iQ2 Unit Handpiece assembly only
644035
SmartLite iQ2 Unit Charging Base assembly only
644032
SmartLite iQ2 Unit Battery Door Replacement
644034
9