The
Exit icon can be selected to exit from the program without
performing the calibration.
ATTENTION
- It is essential to perform the calibration procedure with the greatest care; any
errors in this phase will have repercussions on all the subsequent distance
measurements.
- On completion of the sensor calibration procedure, the sensitivity calibration
should also be carried out.
It is possible to switch from one centred position to the other by selecting the
Position search icon; whenever this icon is selected, the system switches
from the centred position of one side to that of the other. The automatic position
search on the second side can also be carried out by pressing the START button
with the guard raised.
This function is only active if it is enabled in the settings.
Visual check on roundness of the wheel.
This function allows the wheel to be started up at low speed with the guard open.
This makes it possible to perform a visual check for any geometrical irregularities of
the rim and the wheel.
After displaying the list of utility programs:
- select the
- select the
time required to make the check on the wheel. When the
the wheel shaft locking device is activated automatically.
This balancing machine allows three different operators to work at the same time,
thanks to its three different working environments.
- To recall a working environment, select the
after displaying the list of utility programs.
- A submenu appears on the right, displaying three different working environments
(operator 1,2,3).
The yellow selection rectangle is located on the current operator.
- Use the arrow keys
ET 88 operator's manual
Automatic position search (RPA)
Recall other icons icon;
Visual check icon and keep the
Working environments
and
, move the selection rectangle to the operator
key pressed for all the
key is released,
working environment icon.
GB