- Completely undo the screws which fix the front clamping bracket (A, fig. 5).
Remove the retainer bracket (B, fig. 5)
- Remove the monitor from its packaging and fit the supporting foot.
- Place the monitor on the support so that the foot is centred and is touching the
front of the support itself.
- Adjust the height of the front bracket so that the foot of the monitor cannot move.
Lock the bracket in place by tightening the fixing screws.
- Fit the retainer bracket (B fig 5) and secure it with the bolts and the relative
washers provided.
- Take the power supply lead from the monitor packaging and connect one end of
it to the socket on the back of the monitor and the other end to the socket on the
back of the balancing machine body (C, fig. 5a).
- Connect the monitor signal cable (D, fig. 5a) to the nine-pin connector on the back
of the body.
- Any excess cable length can be stowed inside the window (E, fig. 5a) in the top of
the upright which supports the monitor plate.
- Turn the monitor on/off switch to the on position.
- Switch on the balancing machine.
- Adjust the monitor image using the controls on the front and, if necessary, those
on the rear. For information on the adjustment procedure, refer to the manual
inside the monitor packaging.
- After completing assembly of the machine, place it in the chosen position, making
sure that at least the spaces shown in figure 9 are left around it.
- Mark the floor at the points where the fixing holes have to be made (A, B fig. 6).
- Drill holes in the floor with a drill-bit of suitable diameter, insert the expansion
plugs and position the machine in line with the holes.
- Fix the left-hand front foot (B fig.6), fitting the screws and the relative washers in
the order shown in the diagram.
- Tighten the screw until the rubber foot and PVC washer are slightly compressed.
- Then secure the right-hand side of the machine by means of the two holes on the
cross-beam (lift side).
- Adjust the adjustable rest (C, fig.6) so that the machine is standing firmly on the
floor and then tighten the lock-nut on the adjuster bolt.
- Remove the safety screw (A, fig. 8) which prevents the lift carriage from moving
during transport.
- Fit the lift handle into the wheel support plate and fix it in position using the 6
screws provided (B, fig. 8).
- Clamp the control pipelines to the plate as shown in figure 8a.
- Connect the pipeline marked with the coloured band (C, fig. 8a) to the snap
connection inside the lift column.
- Connect the other pipeline to the joint inside the column (D, fig. 8a).
- Fit the flange support pin (E, fig. 8) on the accessories cabinet.
62
Fitting the monitor (fig. 5)
Fixing the machine to the floor (fig.6)
Fitting the lift (fig.8)
ET 88 operator's manual