- Connect the sensor cable to the connector on
the side of the box (A, fig.8c)
- Adjust the length of the ultrasonic sensor cable
near the connector (A, fig. 8c) with a closed guard
to avoid the deformation of the connector itself
during handling of the wheel guard.
- Then lock the cable through the supplied strap
(A, fig. 8a). Any excess cable in the object will
be inserted and locked (by means of the bases
already present) inside the sensor support.
To access inside the sensor stand, remove
the plastic cover by unscrewing the four fixing
screws (Fig. 8d).
EM9780 plus - EM9780 C plus AutomaticLine - Operator's manual
8b
- check and eventually act on the ultrasonic sensor
holder until the required distance between the
calibration template and the support itself (Fig.
8e) is reached, proceeding as follows:
8c
1. Fix the ultrasonic sensor calibration template
in the kit using the centering accessories on
the shaft of the oscillating unit;
2. Lower the wheel guard;
CAUTION
Lowering the wheel guard enables the launch of
the swinging group with the blocked template
!!!
3. Align the ultrasonic sensor calibration template
to the ultrasonic sensor support and test its
distance using a meter, ie:
a. 295mm (tolerance +/- 5mm)
8d
8e
UK
53