10.15.31 RTA GMD02/B MODULE – Power unit
The RTA GMD02/B module is a control for the step
motors and is used with different settings to power the
ducking step motors and the yarn suppliers on the
optional PYF.
FUSES
F1) 10A fuse to protect the 36V power supply.
CONTROL COMPONENTS
1) Orange
LED
control
command. Always off.
2) Red LED control alarm. Comes on when control
is in emergency state.
3) Yellow LED checks the temperature. Comes on if
control exceeds set temperature.
4) Green LED indicates the control has 100% of its
power
supply.
Comes
movement command.
5) Green LED indicates the presence of tension.
Always on.
F
1
disabled
by
external
on
with
the
motor
SANTONI S.p.A.
10.15.31 MÓDULO RTA GMD02/B-Grupo de potencia
El módulo RTA GMD02/B
motores paso
a paso y es utilizado, con seteados
diferentes, tanto para alimentar los motores paso a paso
del desequilibrio cómo los motores de los alimentadores
de hilo del opcional P.Y.F.
FUSIBLES DE PROTECCIÓN
F1) Fusible 10A protección alimentación 36V
COMPONENTES DE CONTROL
1)
Led naranja accionamiento deshabilitado desde
comando externo. Siempre apagado
2)
Led rojo alarma accionamiento. Se enciende cuando
el accionamiento está en emergencia.
3)
Led amarillo control temperatura. Se enciende si el
accionamiento está en sobretemperatura
4)
Led verde accionamiento con corriente al 100%. Se
enciende cuando
motor
5)
Led verde presencia tensión. Siempre encendido.
460
1
2
3
4
5
es un accionamiento para
existe el comando movimiento
REVISION 1.1