DESCRIPTION
Conveyor belt R
Conveyor belt
feeding unit B
Belt feeding reduction gear
(if not lifetime lubricated) C
Epicyclic speed variator
of conveyor belt
(optional device) D
Working units S belts
Belts O of brush-type cleaning
roller unit - Scotch polishing check
roller unit (optional devices)
Table lifting unit F
Table reduction gear G
(if not lifetime lubricated)
Table lifting unit chain H
Compressed air regulator Check bowl and filter
I
Automatic positioner
(optional device) N
All manuals and user guides at all-guides.com
MANUTENZIONE
MAINTENANCE
INSPECTION
Visual inspection
Tensioning and centering 400 h
check
Outer visual check
Oil level check
Change oil
Oil level check
Change oil
Tensioning and wear
check
Tensioning and wear
Outer visual inspection
Oil level control
Change oil
Visual inspection
Stretching check
Precision check
INTERVALS
8 h
Weekly
Yearly
40 h
200 h
After the first 400 working
hours and after:
- every 5.000 h (or 2 years) right level (para. 7.8, 7.10)
(mineral oil)
- every 18.000 h (or 4 years)
(synthetic oil)
200 h
After the first 200 working
hours and then every 2.000 with new MV oil, up to the
h (or 1 year)
200 h
800 h
40 h
200 h
After the first 600 h
and then:
- every 8.000 h (or 3 years)
(mineral oil)
- every 25.000 h (or 6 years)
(synthetic oil)
200 h
400 h
40 h
1500 h (or 1 year)
7.7
7
OPERATIONS
Clean with a vacuum
cleaner (para. 7.1)
Clean with a solution of
water and alcohol (para. 7.6)
Adjust (para. 7.6)
If necessary, adjust
correctly the conveyor
belt (para. 5.10)
Clean outer surfaces with
a vacuum cleaner
If need be, fill with MR oil
(par. 7.8, 7.10)
Drain the used oil and fill
with new MR oil up to the
Fill with MV oil, if
necessary (para.7.8, 7.10)
Drain the used oil and fill
right level (para. 7.8, 7.10)
Tension properly or replace
whenever necessary
(Para. 7.11-9.6)
Stretch them correctly
or replace them, if need be
(Para.7.9 - 9.4)
Clean outer surfaces with
the vacuum cleaner
If need be, fill with MR
oil (para. 7.9, 7.10)
Drain the used oil and fill
with new MR oil, up to
the right level (para. 7.9,
7.10)
Clean with benzine and
lubricate with CTN oil
(Para. 7.10)
If need be, stretch the
chain correctly
(Para. 7.7)
Drain the condensate
possibly present in the bowl
L and clean filter M
with benzine and a
compressed air jet
Carry out a measuring
test with a sample panel
(Para. 5.11)